3 installing the bfs series bag filter – Sterling FILTRATION AND SEPARATION SYSTEMS SGM-250A User Manual

Page 12

Advertising
background image

Page 12

Water Management Systems and Products

Complete the installation of your Centri-Separator system by
plugging the unit into a 110-volt source of electricity. The Centri-
Separator system is now ready to use.

3-3 Installing the BFS Series Bag Filter

Selecting an Installation Site

Place the unit on a suitable and level foundation, preferably a
concrete floor or pad and near the pump for best operation.

Use a fork lift truck when moving the larger units to avoid damage.

Installing Piping

Be sure that piping to the unit has a bypass circuit. The bypass
circuit allows replacement of bag filter without interruption of
service. Connect to the inlet and outlet as labeled on filter housing.
Solids will collect inside the bag filter preventing spill over when
the bag is removed. Always run piping full size. Filter housing
maximum operating pressure is 150 psi.


3-4 Installing the SWF Series Full Flow Stainless

Steel Filter

Selecting an Installation Site

Place the unit on a suitable and level foundation, preferably a
concrete floor or pad and near the pump for best operation.

Use a fork lift truck when moving the larger units to avoid damage.

Installing Piping

Be sure that piping to the unit has a bypass circuit. The bypass
circuit allows for removal of the unit for servicing without
interrupting water service. Connect to the inlet and outlet as
labeled on the housing. Solids will collect in the bottom of the
housing where it will be purged out of the system. Always run
piping full size. Filter housing maximum operating pressure is 100
psi.