5 operation, 1 sand and gravel automatic backwash filter, Adjusting timer – Sterling FILTRATION AND SEPARATION SYSTEMS SGM-250A User Manual

Page 14: Important, Page 14 water management systems and products

Advertising
background image

Page 14

Water Management Systems and Products

5 Operation

5-1 Sand and Gravel Automatic Backwash Filter

Adjusting Timer

Adjust the time control of the SGM-250A if desired. The factory
set timer is set to backwash four minutes every 24 hours.
Frequency and duration may be reset as required. See diagram
below to adjust timer.





















To change the length of backwash time, rotate the complete dial
assembly until the red arrow is at 11:00. Loosen the center screw
and lift the black, yellow, and white dials together pointing to the
desired time to on the red scaled dial. Lift the black knob and the
red dial pointer to 6 on the white-scaled dial. Then lift the black
knob pointer to 6 on the yellow-scaled dial. Tighten screw. Rotate
the complete assembly until the red arrow is pointing to the rib on
the pressure box (6:00 position). The timer will now back wash for
six minutes.

Important!

Make sure gears are engaged before tightening screw

Y

A

D

F

O

E

M

I

T

M A N U A L

E

M

I

T

N

O

I

T

A

R

E

N

E

G

E

R

D A Y

REGEN ERA TIO N

For manual regeneration, move
lever in direction of arrow as far

as it will go - then release.

1. Set skipper wheel so that

"TO-DAY" or number one is

opposite arrow.

Skipper wheel.

2. Set time of day at which unit

is to regenerate by loosening

this screw, and turning this dial

in either direction so that arrow

points to desired regeneration

time in the window of the black

dial.

Then tighten screw.

3. Set time of day by lifting up

yellow dial and turning it in

either direction until actual time

is opposite arrow.

Red
Dial

White

Dial

Yellow

Dial

Lift tabs on skipper wheel

corresponding to days

regeneration as desired.

Advertising