-63

Appendix

User service screw
(for lamp unit cover)

AC socket

5

Insert the new lamp unit.

Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.

6

Replace the lamp unit cover.

Align the lamp unit cover and slide it to
close. Then tighten the user service
screw to secure the lamp unit cover.

Info

If the lamp unit and lamp unit cover are not
correctly installed, the power will not turn
on, even if the power cord is connected to
the projector.

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp.

Info

Make sure to reset the lamp timer only
when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.

You can also reset the lamp timer via the
LAN.
(Refer to the SETUP MANUAL on the sup-
plied CD-ROM for details.)

1

Connect the power cord.

Plug the power cord into the AC socket
of the projector.

2

Reset the lamp timer.

While simultaneously holding down

"

,

ENTER

and

MENU

on the projector,

press

STANDBY/ON

on the projector and

keep all four buttons pressed down until
the lamp indicator starts blinking green.

“LAMP 0000H” is displayed, indicating
that the lamp timer is reset.