Troubleshooting guide (cont'd) – SeaLand 111 User Manual

Page 7

Advertising
background image

7

4. Flush ball will not open.

5. Flush ball does not open

completely.

Applies to

short-base units mounted

on step or riser only.

6. Water does not shut off in

toilet (toilet overflows).

7. Hand spray unit leaks.

8. Water does not enter toilet

bowl properly.

9. Water is leaking from

water valve.

10. Water is leaking from

bottom of toilet base.

11. Water is leaking from rear

of toilet bowl.

12. Water is leaking from the

base/toilet connection.

a. Broken shaft.

b. Shaft not fully engaged in the

spring cartridge.

a. Floor flange interferes with flush

ball rotation.

a. Not enough clearance between

cam strap and top of water valve

cap.

b. Dirt lodged in water valve seal.

c. Worn or defective water valve.

d. Worn or defective spring cartridge.

a. Hand sprayer is defective.

a. Insufficient water flow rate at toilet.

b. Water valve clogged.

c. Plugged rim wash holes in toilet.

a. Water valve body cracked due to

freeze damage.

b. Water line connection is loose or

not seated properly.

c. Defective water valve.

d. Stripped threads.

a. Toilet is not secured to floor.

b. Worn or defective toilet mounting

floor seal.

c. Cracked base.

d. Worn or defective floor flange.

a. Worn or defective vacuum

breaker.

b. Loose vacuum breaker.

c. Cracked or defective toilet bowl.

a. Band clamp may be loose.

b. Ball/bowl seal may be worn

or defective.

a. Replace shaft.

b. Put pressure on shaft from under

the flush ball (pushing into spring

cartridge) until it engages. You

may have to rotate flush ball

slightly until shaft lines up with

square in spring cartridge.

a. Loosen mounting bolts and push

toilet base back. If this does not

solve problem, install a SeaLand

Universal Mounting Kit (part no.

3039, 3040, or 304) with

existing floor flange.

a. Adjust cam strap to have .02"

- .06" (.5mm - 1.5mm) clearance

with top of water valve cap.

b. Dissassemble and clean water

valve.

c. Replace water valve.

d. Replace spring cartridge.

a. Replace hand sprayer.

a. Check water flow rate at toilet.

Rate should be 2 gpm (7.6 lpm)

at toilet.

b. Remove and clean screen

located at inlet of water valve.

c. Clean holes. If still a problem,

replace the toilet bowl.

a. Replace water valve.

b. Insure that threads are not cross-

threaded and tighten.

c. Replace water valve.

d. Replace water valve.

a. Tighten toilet mounting bolts.

b. Replace floor seal between floor

flange and toilet base.

c. Replace base assembly.

d. Replace floor flange.

a. Remove white cap from vacuum

breaker. Flush toilet. If water

leaks during flush, vacuum

breaker needs to be replaced.

b. Secure vacuum breaker

connection. If loose, push

breaker into bowl.

c. Replace toilet bowl.

a. Remove plastic base cover and

tighten the band clamp.

b. Replace ball/bowl seal.

TRoubLeShooTING GuIDe (cont'd)

problem

possible Cause

Service Instructions

Advertising