Basic Functions

Motion Detection Function

This function instructs the camera to detect movement
within the monitoring area and then send an alarm
signal automatically.
The Detect signal goes out through the serial command
(VISCA) communication line.

Features

• You can set a frame for the detection range of 12

(horizontally)

× 8 (vertically) blocks.

• You can set up to four frames.
• When the motion is detected in the set frame, the

Alarm Replay VISCA command is sent.

• The threshold level for detection can be set (common

to four frames).

• The interval of alarm detection can be set up to 256

seconds in units of one second.

• You can set on/off for each frame.
• When the Block Mode is set to ON, the Alarm Reply

command is not sent. Use this mode for checking
when the camera is installed or for confirming the
camera operation.

• The frame number is also sent with Alarm Replay to

report in which frame the motion has been detected.

Frames

Setting frames

You can set the frame by assigning the starting point
and terminating point vertically and horizontally. You
can set up to four frames.

When motion is detected within the rage
where frames overlap

The alarms are sent for both frames.

14hex (20(10))

14hex (20(10))

At this position, the
alarm for frame 3 is
sent.

Within this overlapped
range, alarms are sent for
both frame 3 and frame 4.

Frame 1

Frame 2

Frame 3

Frame 4

mm

Setting Mask
See “mm: Mask setting list” in “Parameters” on page 15.

pp

Sets the center position “x” of the Mask on screen.

qq

Sets the center position “y” of the Mask on screen.

rr

Sets the half value “w” of the Mask Width.

ss

Sets the half value “h” of the Mask Height.
See “pp: x, qq: y, rr: w, ss: h” in “Parameters” on page 15.

Non Interlock Mask

Command: 8x 01 04 6F mm 0p 0p 0q 0q 0r 0r 0s 0s

FF

Parameters:

Commands: Mask does not interlock with pan/tilt.

The limitations of parameters are as follows.
(hexadecimal representation)
x: ±50h
w: ±50h
y: ±3ch
h: ±3ch

Note

When the Set Mask command and the Non Interlock Mask
command are set to the same mask, the command set later