Eclipse, Spectral sensitivity characteristics, Vibration specifications – Sony FCB-EX1010 User Manual

Page 19

Advertising
background image

19

Basic Functions

Spectral Sensitivity
Characteristics

Use the graph as a reference value. (We can not
guaranttee these values.)
This data is measured when the IR cut filter is
removed and the characteristics of the lens and optical
source characteristics are ignored.

Vibration
Specifications

Test Method (Random vibration)
• Fix the camera at the four fixation points of the base

using M2 screws.

• Perform the random vibration test under the

following conditions in the X, Y and Z directions for
20 minutes in each direction.

• The camera vibration specification is to have no

malfunction after this test.

Power spectrum density

Effective overall value

Test time

5 to 50 Hz

4.14 m

2

/s

3

{0.043 G

2

/Hz}

50 to 100 Hz

–36 dB/oct

14.3 m/s

2

{1.46 G}

20 minutes

Eclipse

When designing the housing, refer to the dimensional
allowance as shown in the figure below.

Advertising