Danaher Motion Superior Electric

SS2000MD4

16

400030-043 Rev G

4.7 S

IGNAL

S

PECIFICATIONS

4.7.1 Connector Pin Assignments

All connections are made via the 4-pin terminal strip (J2).

Pin Assignment

1

OPTO

2

PULSE

3

DIR

4

AWO

4.7.2 Signal Descriptions

OPTO

Opto-Isolator Supply

User supplied power for the opto-isolators.

PULSE Pulse Input

A low to high transition on this pin advances the motor one step. The step size is
determined by the Step Resolution switch setting.

DIR

Direction Input

When this signal is high, motor rotation is clockwise. Motor rotation is counter-clockwise
when this signal is low.

Clockwise and counter-clockwise directions are properly oriented when viewing the
motor from the end opposite the mounting flange.

AWO

All Windings Off Input

When this signal is low, AC and DC current to the motor will be zero. There is no

holding torque when the AWO signal is low.

If you are using the drive with an MX2000, SS2000I or SS2000I-V
control, the READY input and the OPTO input on the control must be
jumpered together.

4.7.3 Level Requirements

OPTO

Voltage .................... 4.5 to 6.0 VDC
Current..................... 16 mA per signal used

Other Signals

Voltage

Low................... 0.8 VDC

0.0 VDC

High .................. OPTO

OPTO - 1 volt

Current

Low................... 16 mA
High .................. 0.2 mA