FUNCTION

Select 7

×

9 (half dot) font

CODE

<ESC> “M”
(1B)

H

(4D)

H

OUTLINE

Selects 7

×

9 (half dot) font.

Refer to User’s manual for the maximum number of print
columns.
When the power of the printer is turned on, 7

×

9 (half dot)

printing is automatically selected.
This code valid only when received at the beginning of a line.

FUNCTION

Select 5

×

9 (2 pulses = 1 dot) font

CODE

<ESC> “P”
(1B)

H

(50)

H

OUTLINE

Selects 5

×

9 (2 pulses = 1 dot) font.

This code is valid only when received at the beginning of a
line.

FUNCTION

Select 5

×

9 (3 pulses = 1 dot) font

CODE

<ESC> “:”
(1B)

H

(3A)

H

OUTLINE

Selects 5

×

9 (3 pulses = 1 dot) font.

This code is invalid when using SP311F SP341F SP321S.
This code is valid only when received at the beginning of a
line.

FUNCTION

Select expanded character mode

CODE

<SO>
(0E)

H

OUTLINE

Data following this code is printed in double-width charac-
ters.
Same as <ESC> “W” “1” or <ESC> “W” <1>.