SCOTSMAN WOOD FURNACE – INSTRUCTION MANUAL

Scotsman

Oct-06

14

The blue heating wire from the wood fan limit control on high speed.

This relay will disconnect the circulation fan low speed switch and connect the high
speed to the blower motor when there is a call for heat.

Items required:

o

Switching Relay R4222D 1013 (120 V Coil, 12 amp @ 120 Vac), or equivalent.

o

Junction box (4” x 4”) and cover.

o

Square extension box (4”x 4” gyproc extension).

o

Two plastic universal bushings or junction box connectors.

o

White wire (12”), two insulated spade connectors.

o

Black wire (6”), two insulated spade connectors.

o

Brown wire (12”), two insulated spade connectors.

o

Yellow wire (12”), two insulated spade connectors.

o

Two cabinet mounting screws.

Low Speed Switching Relay Installation Instructions

1) Turn OFF POWER to the oil furnace and wood furnace.

2) Mount the switching relay in a junction box, in the blower compartment near the

blower motor and motor wires. (If possible mount relay on rubber or foam pad to
reduce noise in ductwork).

3) Remove the white neutral wire from the blower motor, and connect it to a selected

neutral side of the relay coil.

4) Connect the white wire (item 2) to the second spade of the selected neutral side of

the relay coil, and the other end into the blower neutral wire location (where initial
white wire was removed).

5) Remove the black high-speed wire from the blower motor (this should be the

selected blower heating speed), and connect it to the power side of the relay coil
(no relay spade #).

6) Connect the black wire (item 3) to the second spade of the selected power side of

the relay coil, and the other end of the wire on to one side of the normally open
contacts (relay spade #1).

7) Connect the brown wire (item 4) to the high-speed connection on the blower motor,

and the other end of the wire on to the other side of the normally open contacts
(relay spade #3).

8) Remove the yellow low-speed wire from the blower motor (this should be the

selected low-speed in the furnace wiring box), and connect it to one side of the
normally closed contacts (relay spade #4).

9) Connect the yellow wire (item 5) to the low-speed connection on the blower motor,

and the other end of the wire on to the other side of the normally closed contacts
(relay spade #5).

10) Turn ON POWER to the oil furnace and wood furnace. Check relay operation.