SCOTSMAN WOOD FURNACE – INSTRUCTION MANUAL

Scotsman

Oct-06

2

KERR SCOTSMAN Wood Furnace Model DB-101-ADD

Tested and Listed by:

Energy Testing Laboratory of Maine

Certified by the Canadian Standards Association (CSA) Sept. 1981

COSP No. WCP 001 – Free-Standing
COSP No. WCP 005 – Add-On

Manufactured by: Parrsboro Metal Fabricators Ltd.

P.O. Box 637, Crossroads
12118 Highway 209
Parrsboro Nova Scotia, Canada
B0M 1S0

SPECIFICATIONS

Length

39”

Width

29”

Height

44 1/2”

Shipping Weight

392 lb.

Fire Box 1/8”plate Length

36”

Diameter

23”

Secondary Heat Exchanger

14 gauge steel

Fire Box Door

Cast Iron

13” x 13”

Warm Air Plenum

32 1/4” x 25 1/2”

Return Air Plenum

N/A

Air Filter Size

20” x 20”

Blower Size

G9 – 10

Blower Motor

1/4 hp

C.F.M.

1000 (Required)

Smoke Pipe

7” Inside Diameter

Floor to smoke pipe center

38 3/4”

Output (max)

140,000 Btu/h

Fuel

Wood 30” logs

Electrical Rating

Volts 120, Cycles 60, Amps 15

NOTE – Keep this manual in a safe place for future reference. Follow manual carefully
for the correct way to install and operate this unit.

CAUTION – Do not fire this unit until operating instructions have been read and fully
understood.

INSTALL WOOD FURNACE ONLY ON A FURNACE DUCT SYSTEM

AND CHIMNEY THAT ARE IN GOOD CONDITION.

SAVE THESE INSTRUCTIONS