Sony Ericsson CDP-CX220 User Manual

Page 12

Advertising
background image

– 12 –

Aging Method

1. Change the

[COMMAND MODE]

switch (S901) on set to

[CD1]

.

2. Turn ON the power of the unit. Open the front cover.
3. Press the

[AGING START]

button of the remote commander

for aging mode (J-2501-123-A).

4. When the disc set mode is set, the

· and P LEDs blink.

5. Rotate the JOG dial. The slits (No. 40, 80, 120, 160, 200) for

setting the discs will come forward. Insert the discs into these
slits. Do not set the discs in other slits.

6. Set whether the self-protection function during errors is

equipped with the unit. Press the

[REPEAT]

button. If “RE-

PEAT” is displayed on the Fluorescent indicator tube, it means
the function is provided. If “REPEAT” is not displayed, it
means the function is not provided.

7. Press the

· button.

8. The

· LED blinks, the aging mode is set, and aging is

started.

9. The aging cycle lasts 3 minutes. If errors occur during aging,

the error number will be displayed on the Fluorescent indica-
tor tube. (Refer to the following table for the details of the
errors.)

10. Aging will be repeated as long as no errors occur.
11. After each aging cycle, the number displayed on the Fluores-

cent indicator tube will increase.

12. To end aging, press the

I/

u button

Error Display

Error code

1 2 0

E r r 0 1

  

  

Disc number

Error code

Code number

Name

Contents

Err 01

DISC sensor check 1

No disc in the specified slit

Err 02

DISC sensor check 2

Disc in other slits

Err 03

Table operation check 1

Table motor current over

Err 04

Table operation check 2

No table sensor input

Err 05

Loading operation check 1

Load in timeover

Err 06

Loading operation check 2

Load out timeover

Err *1

BU related check 1

Access timeover

Err *2

BU related check 2

High speed search NG

Err *3

BU related check 3

Q data read error

Err *4

BU related check 4

BU operation (from focus search to until signal can be read) timeover

Err *5

BU related check 5

GFS monitor error

Err *6

BU related check 6

Focus cannot be imposed by focus search

Err *7

BU related check 7

Auto focus bias adjustment cannot be performed

The * numbers mean the following according to the state of the unit during aging

2 : From checking to end of TOC read
3 : From end of TOC read to end of last track playback
4 : From end of last track playback to end of first track playback

Advertising