Putting the transmitter into operation

8

Putting the transmitter into operation

Setting up the transmitter on a flat surface

̈

Clean the base of the transmitter where you want to fix the device feet.

̈

Fit the device feet to the four corners of the transmitter.

̈

Place the transmitter on a flat, horizontal surface. Please note that the device feet can
leave stains on delicate surfaces.

Mounting the transmitter into a 19” rack

̈

Slide the transmitter into the 19” rack.

̈

Secure the rack mount “ears”

³

to the rack using four screws (not included in the

delivery).

Connecting the antennas

You have the following options:

• For professional use, we recommend connecting a remote antenna and, if necessary, using

Sennheiser antenna accessories (see next section and the chapter “Connecting several
transmitters to a remote antenna” on page 9).

• If the transmitter is to be put into operation without a large amount of installation work,

you can:

– connect the supplied rod antenna to the rear of the transmitter (see page 9) or

– use the optional GA 3030 AM antenna front mount kit (see page 9).

Do not fit the device feet when mounting the transmitter into a 19” rack.

CAUTION!

Risks when rack mounting the transmitter!

When installing the device in a closed or multi-rack assembly, please consider that, during
operation, the ambient temperature, the mechanical loading and the electrical potentials will
be different from those of devices which are not mounted into a rack.

̈

Sure that the ambient temperature within the rack does not exceed the permissible
temperature limit specified in the specifications.

̈

If necessary, provide additional ventilation.

̈

Make sure that the mechanical loading of the rack is even.

̈

When connecting to the power supply, observe the information indicated on the type
plate. Avoid circuit overloading. If necessary, provide overcurrent protection.

̈

When rack mounting, please note that intrinsically harmless leakage currents of the indi-
vidual mains units may accumulate, thereby exceeding the allowable limit value. As a
remedy, ground the rack via an additional ground connection.