Sanyo PLC-XM100L User Manual

Page 11

Advertising
background image

PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications

11/28

6.4 Operation Requirements

6.4.1

In the following status of projector, Available Functional Execution Commands are limited.

Projector Status

Available Functional Execution Commands

Standby Mode

C00: POWER ON

Countdown in process

C00: POWER ON → Countdown is terminated
C01: POWER OFF
C02: POWER OFF → Countdown is terminated
C46: ZOOM -
C47: ZOOM +
C4A: FOCUS -
C4B: FOCUS +
C5D: LENS SHIFT UP
C5E: LENS SHIFT DOWN
C5F:LENS SHIFT LEFT
C60:LENS SHIFT RIGHT

When ZOOM+/-, FOCUS +/-, LENS SHIFTUP/
DOWN/LEFT/RIGHT are executed during Countdown
is in process, POINTER UP/DOWN(C3C/C3D)
become effective, and ZOOM/FOCUS/LENS SHIFT
become enable to control by POINTER UP/DOWN.
*Pointer Command(C3A/CA3B/C3C/C3D)

Cooling Down in process

NONE (No Execution)

Cooling Down due to Abnormal
Temperature

NONE (No Execution)

Abnormal Temperature Status

NONE (No Execution)

Abnormal Power Status

NONE (No Execution)

Abnormal Filter Status

NONE (No Execution)

Power-Save Cooling Down in process NONE (No Execution)

Power Save Status

C00: POWER ON
C01: POWER OFF

Cooling Down in process after OFF
operation due to Lamp Failure

NONE (No Execution)

Input button:Mode2 / Mode3 setting

Although transmit Input source commands, Input
search does not operate.

Note) in above status, the projector returns [ACK] [CR] even if it receives the other command.

6.4.2

Functional Execution Commands are invalid when projector is in standby and “Eco” mode

selected in Standby mode menu.