PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications

24/28

7.4 Status Read Command

Command “CR0” [CR]

Detail

Get the projector’s operating status

Acceptable

“%1” [CR]

%1

”00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to Abnormal Temperature
“88” = Standby after Cooling Down due to Abnormal Temperature
“24” = Power-Save Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after OFF due to Lamp Failure
“81” = Standby after Cooling Down due to Lamp Failure
“2C”= Cooling Down in process after OFF due to
Shutter Management
“8C” = Standby after Cooling Down due to Shutter Management

Response

Unacceptable “?” [CR]

Details for Response

“00” [CR]

Status: Power ON

Normal image is on-screen.

“80” [CR]

Status: Standby

When the status is Standby, Status Read Commands are always accepted, but any

Functional Execution Commands are not accepted except for POWER ON command.

“40” [CR]

Status: Countdown in process

When “Display” in Setting Menu is set to ON, Countdown operation is started by execution

of POWER ON; while “Display” in Setting Menu is set to OFF, the status moves directly to

Power ON without Countdown operation. When “Display” in Setting Menu is OFF,

processing Countdown is not executed and the status quickly moves to Power ON.

“20” [CR]

Status: Cooling Down in process

When the status is Power ON, and then POWER OFF Command (“C01” [CR]) is executed,

it moves to Cooling Down status.

When lamp turns off and about 90 seconds of fan spinning finishes, the above status

automatically moves to Standby (The fan spinning time depends on models.)

This function is intended to cool down lamps and other optical parts, and is quite important

for projector’s reliability. During this time, any Functional Execution Command is invalid.