INTERFACE SPECIFICATIONS

Data format

Communication protocol

A proprietary Sanyo protocol (SSP: Security Serial
Protocol) is used. Use of a special controller for operation
is recommended. To obtain this controller, contact a Sanyo
service center.

Termination settings

When connecting multiple devices, you must make
termination settings on both end devices.
z

Set the RS-485 termination switch of both end devices
to ON.

z

Be sure to set the RS-485 termination switches of all
devices in between (devices other than the first and last
devices) to OFF.

z

If you don’t make the correct termination settings, the
incorrect data will be transmitted to each device.

Example

RS-485 specifications

Mode

Asynchronous

Character length

8 bits

Data transmission speed 2400, 4800, 9600, 19200 bps

Parity check

None

Stop bit

1 bit

RS-485 termination switch settings