While using group function

Symptom

Cause/Remedy

The group function
does not operate.

• While using a disc without group setting, an attempt was made to select

some group-related menu.
, Use a disc with group setting.

A new group cannot
be created.

• This is due to the MiniDisc system limitations (in MD mode only).

Group information has been written to the area where the disc name is
stored. The disc name and track names are recorded in the same area,
which can store a maximum of approximately 1,700 characters. If the
total number exceeds this amount, it is impossible to make group
settings.

While the recorder is connected to the computer

Symptom

Cause/Remedy

The recorder is not
recognized by the
computer.

• The dedicated USB cable is not firmly connected.

, Connect the dedicated USB cable firmly to the recorder and the

computer.

• A USB hub is used.

, Connect the dedicated USB cable directly to the USB port of the

computer.

• Network communication has failed.

, Disconnect the dedicated USB cable, wait at least 2 seconds, and

then reconnect it. If the recorder is still not recognized, disconnect
the dedicated USB cable, restart the computer, and then connect the
dedicated USB cable again.

• When using Windows 2000 Professional, you turned on or restarted the

computer while the dedicated USB cable was connected, and then
disconnected it afterwards.
, Disconnect the dedicated USB cable, restart the computer, and then

reconnect the dedicated USB cable. This problem may be resolved
by updating your Windows operating system so that it contains all
the latest features.

Even though the
recorder is
recognized by the
computer, it does
not operate
normally.

• A USB hub is used.

, Connect the dedicated USB cable directly to the USB port of the

computer.

• You are using the recorder at a place with vibration.

, Use the recorder at a place with no vibration.

The recorder cannot
be used as a storage
device.

• The SonicStage or MD Simple Burner software is active.

, Close the SonicStage or MD Simple Burner software.

• A disc which is not used in Hi-MD mode is inserted.

, Insert a disc used in Hi-MD mode. Only discs used in Hi-MD mode

can be used as a storage media.

020REG.book Page 73 Tuesday, April 12, 2005 11:18 AM