Danger, Cold weather kit, Reconfiguring the fuel system – Siemens SG035 User Manual

Page 11: Standby generator sets specifications, Figure 6.2 — reconfigure the fuel system, Figure 1 — interconnections

Advertising
background image

COLD WEATHER KIT

For cold climates, optional cold weather kit (part
number 0F6148) is recommended. The kit includes:

• Battery Warmer
• 4” Junction Box with hardware
• 6 qt. pack 5W-30 synthetic oil (engine)

RECONFIGURING THE FUEL SYSTEM

NOTE:

All models are configured for natural gas or LP
vapor from the factory.

To reconfigure the fuel system from NG to LP, follow
these steps:

1. Turn the main gas supply off.
2. Remove the carburetor fuel hose from the outlet

port (Port 1) of the demand regulator (Figure
6.2).

3. Remove the brass hose fitting from the outlet port

(Port 1) of the demand regulator.

4. Remove the brass hose fitting with solenoid from

Port 2.

5. Install brass hose fitting into Port 2.
6. Install the brass hose fitting with solenoid into

Port 1.

7. Connect carburetor gas hose to brass fitting.
8. Tighten all clamps and plugs.
9. Make sure fuel supply is of the proper pressure

and type for configuration.

‹

‹

10. Reverse the procedure to convert back to natural

gas.

11. The Dip switch inside the control panel must be

in the LP or NG position when switching to differ-
ent fuels.

Figure 6.2 — Reconfigure the Fuel System

NOTE:

Port 1 is for NG only and Port 2 is for LP vapor
only. No provision for dual fuel has been made.

DANGER

Serious injury or damage may occur if not con-

figured properly. Please consult an Authorized
Service Dealer with any questions.

TO
ALTERNATOR

NEUTRAL

GROUND

CIRCUIT
BREAKER

NEUTRAL

Ground Level
Concrete Slab

STUB-UP AREA

See Install Dwg for

Dimensions

CONTROL PANEL

GENERATOR
CONNECTION
BOX

FRAME RAIL

N1
N2
23
194

186

178

To Generator Control Panel

Utility In

Load
Out

Gen

N1
N2
23
194

183
178

120 Volt +
Neutral
Grd

Battery
Charger
Input

Transfer Switch

CIRCUIT BREAKER SIZE
KW VOLTS / AMPS LUG SIZE
35 240 1 Ø 175 #6 to 300 mcm
35 208 3 Ø 150 #6 to 300 mcm
35 480 3 Ø 60 #6 to 300 mcm

4- # 14 GA
WIRES TO
GENERATOR
CONNECTION
BOX

TO GENERATOR
CONNECTION BOX

Figure 1 — Interconnections

6-2

Standby Generator Sets

Specifications

GenSpec019 Rev.

B 05/06

Advertising