Siemens SG035 User Manual

Page 22

Advertising
background image

Maintenance Level 1

Level 2

Level 3

Level 4

Level5

Tasks

Recom-

Task Required Task Required Task

Task Required Task

mended

Comp. to be done Comp. to be done Comp.

Required

Comp. to be done Comp.

to be done (Date- 3 months/ (Date-

Semi-

(Date- to be done (Date-

Bi-

(Date-

monthly/ Initials) Break-in Initials) annually/ Initials) Annually/ Initials) annually/ Initials)

10 hrs.

30 hrs.

50 hrs.

100 hrs.

250 hrs.

10. Check the engine

accessory drive
belts and fan
coupling device
if equipped for
correct tension,
wear, weather
cracking, and
damage. Replace
as necessary.

11. Check the engine

valve clearance.
Adjust as
necessary.

12. Visually inspect

the unit looking
for leaks, wear or
damage, loose
connections or
components, and
corrosion. Correct
as necessary.

13. Test the engine

and transfer
switch safety
devices. Correct
and/or adjust as
necessary.

14. Initiate an

automatic start
and transfer of
the unit to site
load and exercise
it for at least 1
hour looking for
leaks, loose
connections or
components, and
abnormal
operating
conditions.
Correct as
necessary.

15. Replace the

engine
accessory
drive belts.

16. Check gearbox

oil level (if
equipped).

17. Change gearbox

oil (if equipped).

11-3