Area used

Requirements for emitted interference

interference immunity

Industrial

EN 50081-2: 1993

EN 55022 Class A: 1998

EN 50082-2: 1995

Printed in Germany

Notes on CE identification
The devices comply with the regulations
of the following European directive:

89/336/EEC
Council Directive on the harmonisation
of the legal regulations of member
states on electromagnetic compatibility
(amended by Directives 91/263/EEC,
92/31/EEC and 93/68/EEC).

The product can be used in the residential
sphere (residential sphere, business and trade
sphere and small companies) and in the
industrial sphere.

The precondition for compliance with EMC limit
values is strict adherence to the construction
guidelines specified in this description and
operating instructions.

4. Technical data

General data

Operating voltage

DC 9.6 to 57.6 V safe extra-low voltage (SELV) (redundant inputs decoupled)

Current consumption

typ. 160 mA at 24 VDC
max. 190 mA at 24 VDC

Overload current protection at input

non-replaceable thermal fuse

Dimensions W x H x D

47 mm x 135 mm x 111 mm 1.9 in x 5.3 in x 4.4 in

Weight

230 g

0.51 lb

Ambient temperature

0 ºC to + 60 ºC

32 ºF to + 140 ºF

Storage temperature

- 20 ºC to + 80 ºC

-40 ºF to + 176 ºF

Humidity

10% to 90% (non condensing)

Protection class

IP 20

Laser protection

Class 1 conform to EN 60825

Radio interference level

EN 55022 Class A
Warning!
This is a Class A Equipment. This equipment may cause radio interference if used in a residential
area; in this case it is the operator´s responsibility to take appropriate measures.

Interference immunity

EN 50082-2

Network size

Transition

TP port

F/O port and F/O port

TP port

Propagation equivalent

2 x 42 BT = 84 BT

(1 BT = 10 ns)

TP line length (TP port

TP port)

Length of a twisted pair segment

max. 100 m

(328 ft)

F/O port

According to IEEE 802.3u 100BASE-FX
System attenuation

50/125 µm fiber

8 dB

62,5/125 µm fiber

11 dB

Wave length

1300 nm

F/O line length (example)

50/125 µm fiber

3000 m (9843 ft) maximum

(data on fiber: 1.6 dB/km, 500 Mhz*km)

62,5/125 µm fiber

3000 m (9843 ft) maximum

(data on fiber: 2.6 dB/km, 500 Mhz*km)

Scope of delivery

Ethernet Transceiver 100 Mbps TX/FX incl.

terminal block for supply voltage
Quick reference guide

Order number

Ethernet transceiver 100 Mbps TX/FX

499NTR00100

Accessories

Ethernet SFTP cat5RJ45 cords

490NTW000

ii

Ethernet SFTP cat5RJ45 crossed cords

490NTC000

ii

Ethernet MTRJ/SC 5 m optical patch

490NOC00005

Ethernet MTRJ/ST 5 m optical patch

490NOT00005

Note: The optical patch is made up of two 62.5/12.5 multi mode glass fiber, used in 1300 nano-meter wavelengths.

Ethernet reference Manual

490USE13300

Advertising
This manual is related to the following products: