Table 6. 3-wire control interface characteristics, Sclk, Sdio – Silicon Laboratories SI4734/35-B20 User Manual

Page 9

Advertising
background image

S i 4 7 3 4 / 3 5 - B 2 0

Rev. 1.0

9

Figure 4. 3-Wire Control Interface Write Timing Parameters

Figure 5. 3-Wire Control Interface Read Timing Parameters

Table 6. 3-Wire Control Interface Characteristics

(V

DD

= 2.7 to 5.5 V, V

IO

= 1.5 to 3.6 V, T

A

= –20 to 85 °C)

Parameter

Symbol

Test Condition

Min

Typ

Max

Unit

SCLK Frequency

f

CLK

0

2.5

MHz

SCLK High Time

t

HIGH

25

ns

SCLK Low Time

t

LOW

25

ns

SDIO Input, SEN to SCLK

↑ Setup

t

S

20

ns

SDIO Input to SCLK

↑ Hold

t

HSDIO

10

ns

SEN Input to SCLK

Hold

t

HSEN

10

ns

SCLK

↑ to SDIO Output Valid

t

CDV

Read

2

25

ns

SCLK

↑ to SDIO Output High Z

t

CDZ

Read

2

25

ns

SCLK, SEN, SDIO, Rise/Fall time

t

R

, t

F

10

ns

Note: When selecting 3-wire mode, the user must ensure that a rising edge of SCLK does not occur within 300 ns before the

rising edge of RST.

SCLK

70%

30%

SEN

70%

30%

SDIO

A7

A0

70%

30%

t

S

t

S

t

HSDIO

t

HSEN

A6-A5,

R/W,

A4-A1

Address In

Data In

D15

D14-D1

D0

t

HIGH

t

LOW

t

R

t

F

½ Cycle Bus

Turnaround

SCLK

70%

30%

SEN

70%

30%

SDIO

70%

30%

t

HSDIO

t

CDV

t

CDZ

Address In

Data Out

A7

A0

A6-A5,

R/W,

A4-A1

D15

D14-D1

D0

t

S

t

S

t

HSEN