Electrical Requirements

45

M414905

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

75 Pound Gas and Steam Models

Refer to Table 8 and Table 9.

NOTE: Wire size and breaker ratings were
obtained from the Canadian Electrical Code for
75 C. wire and are intended for use as a guideline
only. Electrical connections should be made by a
qualified electrical contractor in accordance with
all applicable local and national requirements.

NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.

NOTE: Use copper conductors only.

NOTE: Connect to individual branch circuit.

NOTE: 3 Phase Only – Each tumbler must be
connected to its own individual branch circuit
breaker, not fuses, to avoid the possibility of “single
phasing” and causing premature failure of the
motor(s).

Serial Plate Rating

Terminal Block

Connections

Required

Serial Plate Amps

Recommended Circuit

Nonreversing

Reversing

Breaker

Rating

Wire Size

AWG (mm

2

)

120V/60Hz/1ph

L1, Neutral and ground

13.8

N/A

20A – 1 pole

12 (3.31)

200-208V/60Hz/1ph

L1, Neutral and ground

7.6

N/A

15A – 1 pole

14 (2.08)

200-208-240V/60Hz/
1ph

L1, L2 and ground

7.6

N/A

15A – 2 pole

14 (2.08)

230-240V/50Hz/1ph

L1, Neutral and ground

6.7

7.0

15A – 1 pole

14 (2.08)

200-208V/60Hz/3ph

L1, L2, L3 and ground

3.8

4.3

10A – 3 pole

14 (2.08)

200V/50Hz/3ph

L1, L2, L3 and ground

3.5

4.5

10A – 3 pole

14 (2.08)

240V/60Hz/3ph

L1, L2, L3 and ground

3.8

4.3

10A – 3 pole

14 (2.08)

230-240V/50Hz/3ph

L1, L2, L3 and ground

3.5

4.9

10A – 3 pole

14 (2.08)

380V/50 or 60Hz/3ph

L1, L2, L3 and ground

1.8

2.1

10A – 3 pole

14 (2.08)

400-415V/50Hz/3ph

L1, L2, L3 and ground

1.8

2.1

10A – 3 pole

14 (2.08)

440V/60Hz/3ph

L1, L2, L3 and ground

1.9

2.1

10A – 3 pole

14 (2.08)

460-480V/60Hz/3ph

L1, L2, L3 and ground

1.9

2.1

10A – 3 pole

14 (2.08)

N/A = Not Applicable

Table 8

F75 Gas Models Only

Serial Plate Rating

Terminal Block

Connections

Required

Serial Plate Amps

Recommended Circuit

Nonreversing

Reversing

Breaker

Rating

Wire Size

AWG (mm

2

)

200-208V/60Hz/3ph

L1, L2, L3 and ground

N/A

6.3

15A – 3 pole

14 (2.08)

240V/60Hz/3ph

L1, L2, L3 and ground

N/A

6.3

15A – 3 pole

14 (2.08)

460-480V/60Hz/3ph

L1, L2, L3 and ground

N/A

3.1

10A – 3 pole

14 (2.08)

N/A = Not Applicable

Table 9