Power switch check – Southbend StratoSteam STRE-5D User Manual

Page 26

Advertising
background image

S

ERVICE

S

TRATO

S

TEAM

E

LECTRIC

C

OUNTERTOP

S

TEAMER

P

AGE

26

OF

56 O

WNER

S

M

ANUAL

1189951

(10/08)

Figure 15

Power Switch Check

L1

L2

L3

1

4

2

5

3

6

Connector

PL1

(socket half)

Contactor

L1

L2

L3

1

4

2

5

3

6

Connector

PL1

(socket half)

1

4

2

5

3

6

Connector

PL1

(socket half)

Test-Lead Positions

for Steps 5 to 7

Test-Lead Positions

for Step 8

Test-Lead Positions

for Step 9

Continuity

No Continuity

Continuity

1. DISCONNECT POWER AT CIRCUIT BREAKER.

2. Remove right side panel.

3. Turn control lever from OFF to ON and then from ON to OFF while looking to see that the power switch is

properly actuating when the lever moves.

4. Disconnect the connector (PL1) that connects the control-panel component wires to the wiring harness.

5. As shown above, place one test lead on terminal L1 of the contactor and the other test lead in position 1 of

connector PL1 (the socket half, which is wired to the control panel).

6. Check for continuity with control lever in OFF position (there should not be continuity).

7. Check for continuity with control lever in ON position (there should be continuity).

8. Repeat steps 5 through 7 with one test lead on terminal L3 of the contactor and the other test lead in position

2 of connector PL1 (as shown above).

9. Place one test lead on PL1 position 1 and the other test lead on PL1 position 2 (as shown above). Check for

continuity with control lever in the ON position (there should not be continuity).

10. If continuity checks are incorrect, replace power switch.

11. Reconnect lead wires.

Advertising