Water-Level-Control Sensor Check

Continuity

1. DISCONNECT POWER AT CIRCUIT BREAKER.

2. Remove the left and right side panels.

3. Remove bottom panel (four screws).

4. Remove insulation cover panel (four nuts).

5. Locate the water-level-control sensor (at the rear edge of the rear element block). Disconnect wires B1 and B2

from the sensor.

6. Place test leads across water-level-control sensor terminals (as shown above) and check for continuity when

the sensor is cool. If no continuity, replace sensor.

7. Reconnect wires and reassemble.