8. Operate heater through 1 heat cycle to ensure combustion-air and

vent pipes are properly connected to concentric vent termination
connections.

fIGure G.

MultI-concentrIc vent terMInatIons

When two or more appliances are directed vented with concentric

vent terminations near each other, each appliance must be

individually vented. NEVER common vent this appliance. When

two or more appliances are direct vented using concentric vent

terminations, the appliances may be vented as shown in Figure H

and Figure I.

figure h.

Concentric Vent Terminations

for Horizontal Direct Venting.

figure I.

Concentric Vent Terminations for Vertical

Direct Venting through a roof.