Periodic maintenance – State Industries Power Vent/Power Direct Vent Gas Models User Manual

Page 37

Advertising
background image

37

ventInG sYsteM InspectIon

At least once a year a visual inspection should be made of the venting

system. You should look for:

1. Obstructions which could cause improper venting. The combustion

and ventilation air flow must not be obstructed.

2. Damage or deterioration which could cause improper venting or

leakage of combustion products.

Be sure the vent piping is properly connected to prevent escape of

dangerous flue gasses which could cause deadly asphyxiation.

Obstructions and deteriorated vent systems may present serious

health risk or asphyxiation.

Chemical vapor corrosion of the flue and vent system may occur

if air for combustion contains certain chemical vapors. Spray can

propellants, cleaning solvents, refrigerator and air conditioner

refrigerants, swimming pool chemicals, calcium and sodium chloride,

waxes, bleach and process chemicals are typical compounds which

are potentially corrosive.

If after inspection of the vent system you found sooting or

deterioration, something is wrong. Call the local gas utility to correct

the problem and clean or replace the flue and venting before

resuming operation of the water heater.

Burner operatIon and InspectIon

Flood damage to a water heater may not be readily visible or

immediately detectable. However, over a period of time a flooded

perIodIc MaIntenance

water heater will create dangerous conditions which can cause

DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

Contact a qualified installer or service agency to replace a

flooded water heater. Do not attempt to repair the unit! It must be

replaced!

At least once a year a visual inspection should be made of the

main burner and the hot surface igniter assembly for proper flame

characteristics and ignition sequences. You should also check for

sooting. Soot is not normal and will impair proper combustion. A visual

inspection of the main burner and HSI igniter assembly should also be

done at least once a year.

Soot build-up indicates a problem that requires correction before

further use. Turn “OFF” gas to water heater and leave off until repairs

are made, because failure to correct the cause of the sooting can

result in a fire causing death, serious injury, or property damage.

Burner cleanInG

In the event your burner or burner air openings require cleaning,

turn the on/off switch to the “OFF” position and allow the unit to cool.

Call a qualified service agency to remove and clean the burner and

correct the problem that required the burner to be cleaned.

houseKeepInG

Vacuum around base of water heater for dust, dirt, and lint on a

regular basis.

Advertising