Parts breakdown – Woodstock D4137 User Manual

Page 2

Advertising
background image

-2-

D4137 Magnetic Switch Instructions

COPYRIGHT © JUNE, 2010 BY WOODSTOCK INTERNATIONAL, INC.

WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT

THE WRITTEN APPROVAL OF WOODSTOCK INTERNATIONAL, INC.

Printed in Taiwan

#12946TS

Thermal Relay Overload Amp

Adjustment Dial: Turn this dial

to the amperage setting speci-

fied by the motor manufac-

turer. Typically, this setting is

100–110% of the amperage load

listed on the motor data plate.

Please note that turning this

dial has no effect on increasing

motor horsepower. If turned too

high, the motor can overheat

and be damaged before the

relay trips.

Trip Indicator: If this window

turns yellow, the thermal relay

has tripped.

Manual Trip Test Lever: If the

thermal relay function is in

question, run the motor and

use a wooden toothpick to slide

the yellow test lever to the

left. If the motor shuts off, the

thermal relay has tripped and is

functional.

OFF Button: When pushed, the current going to the magnetic field

coil is cut, which opens the contactor and cuts power to the motor.

Manual Contactor Override

Lug: When pushed, the

contactor is manually closed for

troubleshooting purposes only.

ON Button: When pushed,

power is sent to the magnetic

field coil, closing the contactor

and sending power to the

motor.

Manual/Auto Reset Lever: In

the up position, the thermal

relay is in manual reset mode.

This means you must re-install

the outside cover and push

the red OFF button, then push

the green ON button to reset

the thermal relay. In the down

position, the thermal relay will

automatically reset when it has

cooled.

Reset Button: When pushed,

the thermal relay is reset,

clearing the yellow trip indica-

tor window.

REF PART #

DESCRIPTION

REF PART #

DESCRIPTION

101

XD4115101 SWITCH BOX

107

XD4115107 CONTACTOR RETAINER

102

XD4115102 SWITCH BOX COVER ASSEMBLY

108

XPS106M

PHLP HD SCR M3-.5 X 10

103

XD4137103 DATA LABEL HUFB-16KK

109

XD4115109 CAPTURED GROUND SCR M4-.7 X 10

104

XD4115104 CONTACTOR TECO CU-16 110V

110

XPS10

PHLP HD SCR 10-24 X 1-1/2

105

XD4115105 FIELD SWITCH TECO CNA-1

111

XD4115111 LIQUID-TIGHT STRAIN RELIEF PG-16

106

XD4137106 OL RELAY TECO RHN-10K 22-30A

112

XD4115112 RUBBER SEAL

Parts Breakdown

101

102

103

104

105

106

107

108

109

110

111

112

Advertising