Part preparation – Southwest Specialty Products Sonoran Unvented 36 User Manual

Page 4

Advertising
background image

4

4

Width of firebox

Sonoran 36 45

Sonoran 42 5

1”

Sonoran 48

57”




“A” see above

CAUTION: All gas piping and connections must be tested for leaks-before the installation is completed. After ensuring that
the gas valve is on, apply a soap and water solution to all connections and joints. If bubbles appear, leaks can be detected
and corrected. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANY APPLIANCE IF A
LEAK IS DETECTED.










CLEARANCES

MINIMUM CLEARANCES TO COMBUSTIBLES ARE:

Enclosure:

0" from side of unit to framing

2" from top of unit to combustables

0.5" from back of unit to combustables

In front:

5" from fireplace opening to side wall

12" from Fireplace opening to Mantel

7" from fireplace opening to Top Trim

3" from fireplace opening to side trim

Floor:

No thermal protection required

- Floor in front flush to fireplace opening

- 0" to combustable Floor under unit

Part Preparation

Inspect all parts & using scraper or painter’s tool, clean part corners edges if needed. Make sure all mating surfaces are
clean and free of excess dust & debris. Using 4” brush or a spray bottle, thoroughly moisten all bond surfaces.
THIS MUST BE DONE TO ENSURE PROPER ADHESION OF COMPONENTS AND SEALING OF JOINTS
IF ANY PARTS ARE DAMAGED DO NOT INSTALL CONTACT DEALER FOR REPLACEMENT

FIREBOX


A.

BASE PEDESTAL PREPARATION

Make sure floor is level

B. . CENTER SECTION INSTALLATION (2 PARTS)
The center back wall consists of 2 sections assembled against each other.

DO NOT BOND FRONT & REAR SECTIONS TO EACH OTHER.
Apply a 3” wide X ¼” thick bed of refractory adhesive to base approximately 1”
in from edges of sides and back. (Where sides and back will sit.) Stand both
sections of back wall on base and support while applying adhesive to cover the
join line between front & rear sections. The coating of cement should cover the
seam all around the outer edges of the back wall. This coat should be smooth
but not excessive. (1/8” thick max.)

VFT

CL

Depth of firebox

Sonoran 36 24 ½”

Sonoran 42 24 ½”

Sonoran 48

24 ½”




“A” see above

36”- 52” from corner
42”- 65” from corner
48”- 70” from corner

36”- 73 1/2” - 42”- 91 1/2” - 48”- 99 1/2”