Southwest Specialty Products Sonoran Unvented 36 User Manual

Page 5

Advertising
background image

5

5

WARNING!

DO NOT BLOCK REQUIRED AIR SPACES

WITH INSULATION OR ANY OTHER MATERIAL.
DO NOT OBSTRUCT EFFECTIVE OPENING OF FIREPLACE
WITH ANY TYPE OF FACING MATERIAL.
COMBUSTIBLE MATERIAL MUST NOT BE IN CONTACT
WITH THE BLACK FRONT FACE OF THE FIREPLACE.

6” (side)

*Assemble side walls (bond beam up) to base and back wall assembly.
** Use carpenters square placed on the base {inside firebox} to ensure the walls are plumb and perpendicular to the floor
of the firebox. Using 4’ level make sure the walls are level front to back & side
to side. Proceed with assembly of top section.


*Remember to moisten all mating (bonded) surfaces before applying adhesive.


** Take care to maintain firebox front opening dimensions (square & plumb) or any future installation of glass doors, Etc. will be
difficult if not impossible.


C. TOP SECTION INSTALLATION

A

A

p

p

p

p

l

l

y

y

r

r

e

e

f

f

r

r

a

a

c

c

t

t

o

o

r

r

y

y

m

m

o

o

r

r

t

t

a

a

r

r

t

t

o

o

t

t

h

h

e

e

t

t

o

o

p

p

e

e

d

d

g

g

e

e

s

s

o

o

f

f

t

t

h

h

e

e

c

c

e

e

n

n

t

t

e

e

r

r

s

s

e

e

c

c

t

t

i

i

o

o

n

n

.

.

w

w

i

i

t

t

h

h

a

a

l

l

i

i

b

b

e

e

r

r

a

a

l

l

3

3

w

w

i

i

d

d

e

e

b

b

y

y

¼

¼

t

t

h

h

i

i

c

c

k

k

t

t

r

r

i

i

p

p

o

o

f

f

r

r

e

e

f

f

r

r

a

a

c

c

t

t

o

o

r

r

y

y

m

m

o

o

r

r

t

t

a

a

r

r

a

a

p

p

p

p

l

l

i

i

e

e

d

d

o

o

n

n

t

t

h

h

e

e

e

e

d

d

g

g

e

e

s

s

.

.

A

A

l

l

i

i

g

g

n

n

w

w

i

i

t

t

h

h

t

t

h

h

e

e

b

b

a

a

c

c

k

k

,

,

s

s

i

i

d

d

e

e

s

s

a

a

n

n

d

d

f

f

r

r

o

o

n

n

t

t

o

o

f

f

t

t

h

h

e

e

c

c

e

e

n

n

t

t

e

e

r

r

s

s

e

e

c

c

t

t

i

i

o

o

n

n

.

.









MANTLE CLEARANCES

Woodwork such as wood trims, mantles, and other combustible materials must be placed at least 6 inches away from the
opening of the fireplace.

Combustible material above and projecting
more than 11 1/2 inches from the front face
of the fireplace must be placed at least 12
inches
away from the fireplace opening.
(ref: NFPA std. 8-2.3.3).


Mantles or any other combustible material
also may come up to the side periphery of
the face of the fireplace as long as the
projection from the front face falls within the
limits shown above.

GAS SUPPLY TESTING

NOTE: This section

is intended as a guide for qualified technicians installing gas to this Unvented

Fireplace.


DO NOT CONNECT UNVENTED FIREPLACE BEFORE PRESSURE TESTING GAS PIPING. DAMAGE TO GAS VALVE
MAY RESULT AND AN UNSAFE CONDITION MAY BE CAUSED.

The appliance and it's individual shut-off valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig
(3.5 kPa).


33

o

33

o

o

11

½”

1

2”

Advertising
This manual is related to the following products: