Warning, Operating instructions, Recovering refrigerant – SPX Cooling Technologies ROBINAIR 17700-2K User Manual

Page 14

Advertising
background image

© 2001 Robinair, SPX Corporation

12

RECOVER

RECOVER
VACUUM

VACUUM

CLOSED

CLOSED

RECOVER

RECOVER
VACUUM

VACUUM

CLOSED

CLOSED

VAC-CHARGE

VAC-CHARGE

ENTER

ENTER

R-134A

R-134A

R-134A

R-134A

in Hg

in Hg
VAC

VAC

psi

psi

bar

bar

kPa

kPa

psi

psi

bar

bar
kPa

kPa

RECOVER

RECOVER

CHARGE

CHARGE

OIL INJECT

OIL INJECT

00

00

33

00

00

55

44

00

00

22

00

00

00

55

00

00

44

33

55

4

4
7

7

CLEAR

CLEAR

MENU

MENU

8

8
0

0

1

1

5

5

2

2

VACUUM

VACUUM

START

START

I

0

F1

F1

9

9

6

6

3

3

CHARGE

CHARGE

STOP

STOP

00

00

22

00

00

00

11

00

33

00

22

11

00

00

44

77

55 0

0

22

3

3

0

0

R

R

55

3

3

00

00

4

4

0

0

0

0

2

2 8

8

33

22

11

00

33

00

4

4

0

0

4

4 0

0

88

22

11

00

D

D

R

R

A

A

TT

E

E

00

88

00

11

11

00

00

00

00

88

77

66

00

00

00

55

66

00

77

00

00

11
00

00

99

00

11

00

55

55

11

00

00

11

55

00

0 0

00

00

00

0 0

55

00

00

11

00

55

00

22

11

00

5

5

0

0 0

0

11

33

00

0

0

5

5

00

44 00

00

22

00

55

00

2

2 00

33

00

6

6 0

0

2

2 5

5 0

0

HIGH

HIGH

RECOVERING REFRIGERANT

WARNING

Wear safety goggles when working with refrigerant. Read and follow
all warnings at the beginning of this manual before operating the unit.

1. Connect the power cord to the back of the unit, and plug it into the correct

voltage outlet.

2. Turn on the MAIN POWER and, if necessary, empty the oil drain bottle

located on the right hand side of the unit.

3. Press the

RECOVER

button.

4. If 150 pounds (68 kg) or more of refrigerant has been recovered since the last

filter-drier change, the display reads FILTER WEIGHT XXX lb (XX kg).
Press

START.

NOTE: Refer to the filter change procedure on page 19 of this manual for details
about replacing the filter.

5. Connect the high and low side hoses to the A/C system, and open the coupler

valves.

6. Put the Low Side Valve in the Recover/Vacuum position. Put the High Side

Valve in the Recover/Vacuum position. Press

START

to continue.

7. If the system pressure is below 25 psi, the display reads: LOW SYSTEM

PRESSURE until the pressure increases or the

START

button is pressed. You

may press

STOP

to exit at this point.

8. If the unit has refrigerant in the low-side plumbing, it begins the clearing

process and displays CLEARING IN PROGRESS. If you wish to skip the
clearing operation or stop the clearing prematurely, press the

START

key.

Diagram of Control Panel
During Recovery

Manifold Gauges

Valves Open

Operating Instructions

INST0928