Setup instructions – SPX Cooling Technologies ROBINAIR 17700-2K User Manual

Page 8

Advertising
background image

© 2001 Robinair, SPX Corporation

6

240

240

220

220

200

200

180

180

80

80

120

120

100

100

140

140

60

60

20

20

40

40

160

160

3

3

4

4

2

2

1

1

8

8

7

7

6

6

5

5

340

340

320

320

MLS

MLS

280

280

300

300

260

260

12

12

11

11

10

10

9

9

OUNCES

OUNCES

CLOSED

CLOSED

RECOVER

RECOVER

RECOVER

RECOVER

CLOSED

CLOSED

CLOSE

CLOSE

VACUUM

VACUUM

VACUUM

VACUUM

CHARGE

CHARGE

OIL INJECT

OIL INJECT

2

2

0

0

5

5
8

8

MENU

MENU

CLEAR

CLEAR

7

7

1

1
4

4

START

START

RECOVER

RECOVER

VACUUM

VACUUM

F1

F1

ENTER

ENTER

9

9

3

3
6

6

STOP

STOP

CHARGE

CHARGE

VAC-CHARGE

VAC-CHARGE

FLOW

FLOW

LOW

LOW

HIGH

HIGH

Setup Instructions

IMPORTANT!

The pump must
be running
when adding
oil.

IMPORTANT!

For maximum
performance,
change the
vacuum pump
oil frequently.

NOTE: The vacuum pump is shipped without oil in the reservoir. Before starting
the pump, oil must be added to the pump, or damage to the pump may occur.

5. Press the

START

key to begin the oil fill process.

6. Attach the flexible tube and cap to the oil bottle, and pour eight ounces of

vacuum pump oil into the fill port.

7. Press the

START

key. While the vacuum pump is running, slowly add oil

until the level rises to the center of the reservoir's sight glass.

8. Press the

STOP

key, and replace the black plastic plug on the fill port.

9. Connect the service hoses, open both panel valves, and press

START

.

10. Connect the fill hose to a full source tank.

11. Open the tank valve. Invert the tank and install it on the back of the unit,

making sure to secure the tank strap.

NOTE: If using a refillable tank, install the tank upside down, and connect the fill
hose to the vapor valve.

INST0947

1

2

3

1. Oil Fill
2. Sight Glass
3. Oil Drain

12. Press

START,

and the unit will automatically run a

five-minute vacuum to clear all internal air.

13. After the vacuum is complete, press

START

to begin

filling the internal storage vessel.

14. The unit stops when a sufficient amount of refrigerant

has been transferred to the internal tank, or when the
source tank is empty. Press the

STOP

key to pause the

process. Press

STOP

again to exit, or

START

to

resume. This process takes 15-20 minutes.

NOTE: Add at least 8 lb. (3.6 kg) of refrigerant before
stopping the process to ensure enough refrigerant is available
for charging.

15. When the fill process is complete, you may press

STOP

to exit.

16. The unit is now ready to operate.

NOTE: There is no need to calibrate the scale, because it is
calibrated at the factory.

Advertising