Basic installation & operation – State Industries GSX User Manual

Page 8

Advertising
background image

8

Exhaust Vent to

Ouside of Building

Union

Union

Water

Shut-Off

Valve

Water

Supply- Cold*

Expansion Tank

Pressurize to Equal

Supply Water Pressure*

(Relieve water pressure

on the expansion tank

before adjusting air

pressure.)

Temperature-Pressure Relief Valve

with discharge piped to an

adequate drain. Do not cap or plug.

6” Maximum Air Gap

NOTE: Local codes

may vary.

Drain

Gas Control Valve/Thermostat

Recommended setting of 120°F.*

Metal Drain Pan piped to an adequate drai
NOTE: Drain pan diameter must be at leas
2 inches wider than the diameter of the
water heater.

Sediment Trap

(Drip Leg) 3” Minimum.

Gas Supply

To Fixtures - Hot

Air is drawn in for combustion.
Keep area clean and free from
flammables and flammable vapors.

The water heater must be installed according to all local and state codes or in the absence of local
and state codes, the “National Fuel Gas Code”’ ANSI Z223.1(NFPA 54)- current edition.

INSTALLATION OF RESIDENTIAL GAS WATER HEATER

See Labels and
Installation Instructions
and Use & Care Guide
for clearances.

* NOTE: If on a well system the expansion tank should be set to the maximum pressure of the pump tank.
** White-Rodgers® gas control valve/thermostat shown in this figure. The valve may vary according to model and year.

*Massachusett: Install
a vacuum relief in cold
water line per section
19 MGL 142.

Do not cap or plug.

Union

Manual Gas

Shut-off Valve

Untempered
Hot Water

Tempered Water
To Fixtures

Cold

Water

Inlet

Hot

Water

Outlet

Mixing Valve

(Set to 120°F)

Follow the Mixing

Valve Manufacturer’s

Instructions

BASIC INSTALLATION & OPERATION

Figure 1