Digital Access Keypad Manual

SECO-LARM U.S.A., Inc.

Digital Access Keypad Manual

_____________________________________________________________________________________

_____________________________________________________________________________________

_____________________________________________________________________________________

_____________________________________________________________________________________

_____________________________________________________________________________________

_____________________________________________________________________________________

_____________________________________________________________________________________

Power:
• Operation voltage -- 12-24 Volts AC/DC. No jumper needed to set voltage.
• Stand-by current drain -- 15mA @12VDC.
• Active current drain (press keypad key) -- Under 45mA@12VDC.
• Active current drain (one relay activated) -- Under 80mA@12VDC.
• Active current drain (two relays activated) -- Under 130mA@12VDC.
Outputs:
• Relay output #1 -- 5A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second timed

output or shunt (start/stop) output. Three terminals.

• Relay output #2 -- 1A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second momentary

output or shunt (start/stop) output. Three terminals.

• Tamper output -- 50mA @ 12VDC, N.C. output. Connect to tamper circuit of alarm control panel.

Two terminals.

• Keypad active or alarm output -- Transistor ground max. 100mA @ 24VDC. Switches to ground (-) for 10

sec. when a key is pressed (keypad active output), or switches to ground (-) to indicate a door was forced
open or propped open (alarm output). Single terminal.

• Mantrap (interlock) control output -- Outputs ground (-) for five seconds after relay output #1 is activated,

continues while the door is open. Use to disable a second keypad during this time. Single terminal.

• Ground output -- Steady ground (-), 100mA @ 24VDC. Single terminal.
• Duress output -- Transistor ground (-), 100mA @ 24VDC. If switches to ground (-) after the duress code

is entered. Single terminal.

Inputs:
• Power -- 12-24Volts AC/DC. Two terminals.
• Egress -- N.O., ground (-). Single terminal.
• Door sensor input -- N.C., ground (-). Connect to an N.C. magnetic contact to show if door is opened or

closed, or connect to ground (-) if not used. Single terminal.

• Relay output #1 disable input -- Connect to ground (-) to prevent relay output #1 from operating, or to the

mantrap (interlock) control output of another keypad to disable output #1 while the other keypad is active.
Single terminal.

Code Operation:
• Auto or manual code entry. Up to 100 user codes for relay output #1, up to 10 user codes for relay

output #2. 111,110,000 possible user code combinations.

Auto refresh time during code entry:
• Max. 10 seconds to enter each digit.
• Max. 30 seconds to enter each code.
Dimensions (keypad with back box):
• 4-15/16" x 3-1/8" x 2" (125 x 78 x 51 mm).
Weight
• 18 oz. (510 grams).

SPECIFICATIONS

1. Master Code: The SK-1123-SQ comes pre-programmed with the Master Code set at 0000. Additional codes and/or

data should be programmed at the owner's discretion. However, to ensure security, program a new personal Master
Code to replace the factory-set Master Code as soon as possible.

2. Factory defaults:

PROGRAMMING NOTES

STATUS

1. In programming mode

2. Successful key entry

3. Successful code entry

4. Unsuccessful code entry

5. DAP jumper not replaced

6. In standby mode

7. Output relay activated

BUZZER TONES*

- - -

1 beep

2 beeps

5 beeps

Continuous beeps

- - -

1-sec. long beep**

AMBER LED FLASHES

ON

1 flash

2 flashes

5 flashes

Continuous flashes

1 flash in 2-sec. intervals

- - -

NOTE: * The buzzer can be disabled through programming option 83, ref. pg. 14.

** The output relay activated beep can be disabled through programming option 81, ref. pg. 14.

BUZZER AND LED SIGNALS

The keypad's built-in buzzer and the amber LED can signal the following:

Door forced open alarm

disabled

Output activation announcer

ON

User code entry mode

manual

Keypress beep

ON

Door propped open alarm

OFF

Silent operation

OFF

LED INDICATORS

• Red LED -- Lights while output #2 is activated.
• Amber LED -- Flashes to show the keypad status (see below).
• Green LED -- Lights while output #1 is activated.

4.

Using Duress Codes (Relay #1 only)

: Duress codes are used to activate a separate device silently to alert a guard

or other personnel that a user is operating the keypad under threat. The keypad operates as normal, but a signal is
sent to alert others.
Duress codes do not need to be programmed. All user codes are automatically turned into duress codes by
increasing the first digit of a user code by the number 2. The code is entered the same way as a regular user code.
For example:
User code 4468 can be entered as duress code 6468
User code 9843 can be entered as duress code 1843
User code 8181 can be entered as duress code 0181
NOTE: If a user code is programmed, its duress code is unique and cannot be programmed as another user
code. For example:
If user code 4468 is programmed, its duress code of 6468 is automatically programmed. A user code of 6468 cannot
be programmed.

3. Code operation: User codes are each four to eight digits and are assigned to two-digit IDs. If all the codes have the

same number of digits, the keypad can be programmed for whether the key must be used or not after entering the
code (see programming, option 82, page 14).
The administrator can easily delete the code of one user via the two-digit ID, if the user is no longer authorized to
enter a protected area, without the need to teach the new code to all the other users.
Relay output #1 allows up to 100 user codes, and relay output #2 allows up to 10 user codes.

Master code

0000

User code length

4-8 digit

Main relay output time

1 second

Auxiliary relay output time

1 second

Wrong code lockout

10 tries / 30 sec.

#

Note: Once activated, the duress output continues until a correct user code is entered.

__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

____________________________________________________________________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

__________________________________________________________

Page 12

Page 5

Advertising