Digital Access Keypad Manual

SECO-LARM U.S.A., Inc.

Digital Access Keypad Manual

Cathode

12~24V

AC/DC

power

supply

+

--

Electric

Lock

N.O.

+

--

N.C. N.O.

OR

N.O.

----------------

------------

--------

--------

ST-UV12-S1.0Q

1N4004

Output Relay
N.O. Output for
Fail-secure lock
N.C. Output for
Fail-safe lock

Egress button

(Inside premises)

Additional egress

buttons can be

connected in parallel

(+) (--)
12-24V AC/DC

Output #1
N.C. COM N.O.

Output #2
N.C. COM N.O.

Egress

In

Keypad

Active

Duress

Output

(--

)

Ground

Door

Sensor

Interlock

Ta

mper

N.C.

O/P

1

Inhibit

CONNECTIONING INHIBIT

AUTHORIZATION CONTROL

WARNING

For safety, ensure that no
one is inside the premises
before starting the door
lock inhibit function.
During inhibit, doors
remain locked.

• Connect a 1N4004 diode as close as possible to and in parallel with the DC-powered electromagnetic or electric lock.

This absorbs possible electromagnetic interference to prevent operation of the lock from damaging the keypad. A
1N4004 is not required for AC-powered locks.

• Connect the ground (-) terminal of the keypad to earth to prevent electrostatic discharge from damaging the keypad.
• The connection of relay output #1 disable to output #2, as shown above is optional. When so wired, output #2 is the

inhibit control. To use, program output #2 for shunt on/off operation. When output #2 is ON, relay output #1 will not
work. For example, this can be used to prevent users from entering the protected premises during the evening or
weekend. See programming option 61.

• The green LED lights while relay output #1 is activated to activate the lock.
• The red LED lights to show that relay output #1 is disabled by the activation of output #2.
• Tape all unused wires to prevent short circuits.
WARNING:
• If the inhibit control is used, all personnel must exit the protected premises before output #2 is activated. Otherwise,

personnel in the protected premises will not be able to exit until output #2 is turned OFF.

• The user code for output #2 in this case should be given only to personnel authorized to enter the premises any time.

It should not be given to other users.

TAMPER N.C.

ALARM

CONTROL

PANEL

24-hour N.O.

protection zone,

max. 100mA

DURESS OUTPUT

KEY ACTIVE or ALARM OUTPUT

1.5k

LED

Low
power
piezo
buzzer

+12V

Isolation

relay

+12V

N.O. relay
contact

MAGNETIC

DOOR

CONTACT

(N.C.)

DOOR SENSING

Required for:

• Door Auto Relock
• Door Forced-open Alarm
• Door Propped-open Alarm
• Mantrap (Interlock) Control

The Key Active Output will switch to ground
(-) for 10 seconds whenever a key is
touched. Use to turn ON an LED and/or a
small buzzer to notify a guard, or to energize
a relay to switch ON lights or CCTV camera.

Only one connection option is recommended.
Make sure the current sink does not exceed
the maximum rating of 100mA.

An external power supply and isolation relay
are necessary to drive high power devices
such as lights or CCTV cameras.

RELAY OUTPUT #2

-- Example, to shunt an alarm N.C. zone

Use Normally Open (N.O.) output
remove to shunt a Normally Closed
(N.C.) protection zone of an alarm
system.

Set relay output #2 to Start / Stop mode
(programming option 51)

N.C.

N.C. magnetic contact

To protection zone of an
alarm control panel

OR

WIRING:

Auxiliary Accessories

SM-200

SM-200

Note: If inhibit control
is activated, the duress
output is disabled.

ALARM

CONTROL

PANEL

24-hour N.C.

protection

zone

WIRING:

Example Wiring, with Inhibit Control Authorized

Page 6

Page 11

Tamper

N.C.

Duress

Output

(-)

Ground

Door

Sensing

Keypad

Active

Keypad

Active

Output #2

N.C. COM N.O.

(-)

Ground