4

Stewart Filmscreen Corporation

Installing the AVS

‹

Position the case so that the motor connection is at audience
right. Do not attach any items to the batten or screen assembly,
the door assembly, or the arm assembly.

‹

Ensure that the case is level and plumb.

‹

If the screen is large, secure the case (for example, bolt to the
floor). Attach L-angle mounts to the end plates, if required. Do
not drill into front or back sides of housing to attach mounting
hardware.

AC electrical hook-up

The motor requires standard AC power, hardwired using a Romex
connection. The connection is made to the J-box on the side of the unit
(audience right).

General suggestions for wiring:

‹

Soldering is recommended.

‹

The use of wire nuts is acceptable.

I

NSTALLATION AND

E

LECTRICAL

H

OOK

-

UP

Caution

Professional techniques need to be used when making any
electrical connection. A qualified electrician should perform
these procedures.

Be sure to follow all standard safety procedures for
installing electrical devices.

Do not disassemble or alter the configuration of the motor
or the unit's electrical connections. This may cause injury to
you or damage to the product.

The electrical connection should be made only to the type
of power source indicated on the marking label.

Caution

Do not make any adjustments to the steel cables.

Do not remove or loosen any bolts on the case or spring
arms.

AC connection

Figure 2. AC connection