Bond status sensor – SECO-LARM USA Electromagnetic Lock E-941SA-1200 User Manual

Page 7

Advertising
background image

SECO-LARM

ELECTROMAGNETIC LOCK

SECO-LARM U.S.A., Inc.

7

Wire Length

25ft. 50ft. 75ft. 100ft. 150ft. 200ft. 250ft. 300ft. 400ft. 500ft. 1000ft.

Wire Gauge @ 500mA 20 18 18

18

16

14

14

12

10

--

--

Wire Length

25ft. 50ft. 75ft. 100ft. 150ft. 200ft. 250ft. 300ft. 400ft. 500ft. 1000ft.

Wire Gauge @ 250mA 24 24 22

20

18

18

16

16

14

14

14

24VDC Minimum Wire Gauge:

Wiring Diagram:

Maximum Distance from Power Source to Electromagnetic Lock:

12VDC Minimum Wire Gauge:

Control

Device*

For a complete chart, please visit www.seco-larm.com

Optional SECO-LARM Electromagnetic Lock Accessories:

600-lb.

Models

1200-lb.

Models

E-941S-600/ZQ

E-941S-1K2/ZQ

E-941S-600/LQ

E-941S-1K2/LQ

E-941S-600/PQ

E-941S-1K2/PQ

E-941S-1K2/UQ

E-941S-600/UQ

“L” Brackets

Plate Spacers

“Z” Brackets

(includes 1 “L” Bracket)

Glass Door

“U” Brackets

E-941S-1K2/ZRQ

(Right-side “Z” Bracket

for E-941DA-1K2P)

E-941D-1K2/P

(for E-941DA-1K2P)

Additional

Models

E-941S-1K2/HQ

E-941S-600/HQ

Armature

Plate Holders

Description

*NOTE: Connect switching devices like
push-to-exit switches between the
power source and the positive terminal
on the lock. Connecting switching
devices to the negative terminal may
cause a delay in unlocking.

Position a jumper over

the two middle pins for

24VDC operation

Position two jumpers

on all four pins for

12VDC operation

Voltage Selection Jumpers

Power Supply

Does not include armature plate

The Bond Status Sensor checks
to make sure the door is closed,
and the electromagnet is locked.

Bond Status Sensor:

Green Door is closed and locked
Red

Door not closed and/or locked

Off

Door in use / No power

600PQ and 1K2P models ONLY

LED Indicators:

(600PQ and 1K2P

models ONLY)

Note: Brackets and spacers are not available for E-941SA-300.

Note: E-941SA-300 is pre-wired.