Table 3-10 – StorageTek StorageNet SCSI-3 User Manual

Page 26

Advertising
background image

FCP and SES Commands

3-6

8946121402

Switch Page

If requested using the

Send Diagnostic

or

Receive Diagnostic Result

command, the

SESD returns the response shown in

Table 3-10

.

2

(MSB)

Page Length = 7 (LSB)

3

4

00h

5

80h

6

81h

7

82h

8

83h

9

84h

10

85h

Table 3-10 Switch Page Format

Byte/Bit

Field #

Access

7

6

5

4

3

2

1

0

0

na

na

Page Code = 80h

1

na

na

Reserved

2 .. 3

na

na

Page Length = 404

4 .. 7

na

na

swValid

8 .. 71

0

ro

Current_Date (in ASCII text)

72 .. 135

1

ro

Boot_Date (in ASCII text)

136 .. 199

2

ro

Firmware_Last_Updated_Date (in ASCII text)

200 .. 263

3

ro

FLASH_Last_Updated_Date (in ASCII text)

264 .. 327

4

ro

Boot_PROM_Last_Updated_Date (in ASCII text)

328 .. 391

5

ro

Firmware_Version_Information (in ASCII text)

392 .. 395

6

ro

Switch_Operational_Status

396 .. 399

7

rw

Switch_Administrative_Status

400 .. 403

8

ro

Diagnostics_Result

404 .. 407

9

ro

Number_of_Sensors

Note: na is not available, ro is read only and rw is read/write

Table 3-9 Page Code 0 Format – Supported Diagnostic Pages (Continued)

Byte/Bit

7

6

5

4

3

2

1

0

Advertising