FCP and SES Commands

8946121402

3-15

Send Diagnostic

A SES Application Client can use a

Send Diagnostic

command to configure/diagnose a

logical unit. After the command completion, the SES Application Client sends a

Receive

Diagnostic Results

command. See

Table 3-22

. The

FCP_CDB

format is shown in

Table 3-26

.

A Page Format (

PF

) bit of 1 specifies that the

Send Diagnostic

parameters conform to the

page structure as specified in SCSI-3 Primary Command (SPC), Revision 11a, X3T10/995D,
working draft
. A value of 0 specifies that all parameters are vendor specific. At present, the
SESD only supports the vendor-specific page structures as defined in the

“Switch Diagnostics

Pages”

section.

The

selfTest

,

DevOfL

and

UnitOfL

bits are ignored by the SESD at present.

The Parameter List Length field specifies the length in bytes of the parameter list that shall be
transferred from the SES Application client to the SESD.

Test Unit Ready

An SES Application Client sends a

Test Unit Ready

command to check if the logical unit

is ready. The

FCP_CDB

format is shown in

Table 3-27

.

The SESD returns the status of

GOOD

and

CHECK CONDITION

and a sense key of

NO SENSE

and an additional sense code of

NO ADDITIONAL SENSE INFORMATION

.

Table 3-26 Send Diagnostic Command Format

Byte/Bit

7

6

5

4

3

2

1

0

0

Operation Code = 1Dh

1

Reserved

PF

Reserved

selfTest

DevOfL

UnitOfL

2

Reserved

3 .. 4

Parameter list length

5

Control = 0

Table 3-27 Test Unit Ready Command Format

Byte/Bit

7

6

5

4

3

2

1

0

0

Operation Code = 00h

1 .. 4

Reserved

5

Control = 0