17

Fix with bolts and nuts tightly on a flat and strong floor.
If installed on the wall or roof, make sure to fix the supporter well to prevent it
from shaking due to serious vibration or strong wind.

3. Outdoor Unit Piping Connection

4. Outdoor Unit Cable Connection (see previous page)

Remove the valve caps from the 2-way and 3-way valve.

Connect the pipes to the 2-way and 3-way valves separately according to the required torque.

2. Install and Fix Outdoor Unit

1.Install Drain Port and Drain Hose (for heat-pump model only)

Drain hose
(prepare by user)

Washer

Drain port

The condensate drains from the outdoor unit when the unit operates
in heating mode. In order to protect the environment, install a drain
port and a drain hose to direct the condensate water. Just install the
drain port and rubber washer to the chassis of the outdoor unit, then
connect a drain hose to the port as the right figure shown.

The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the
compressor. After connecting the indoor and outdoor units, evacuate air and moisture from refrigerant
cycle using a vacuum pump, as shown below.

Refrigerant flow direction

2-way valve

(6) Open 1/4 turn

valve cap

(1) Turn

(8) Tighten

(2) Turn

3-way valve

(8) Tighten

(1) Turn

(7) Turn to fully open the
valve

(7) Turn to fully open the valve

(8) Tighten

3-way valve diagram

connect to indoor unit

open position

spindle

service port cap

Service
port

Connect to outdoor unit

Valve core

needle

Vacuum pump

Valve cap

Installation Instructions

Air Purging

Note: To protect the environment, be sure not to discharge the refrigerant to the air directly.

Outdoor Unit Installation

Indoor unit

1

1