Rx100 installation manual V1.17 29 Aug 08.doc

Page 21

BBV Rx 100

Interface Receiver

Addendum to manual for the following dome:

Merit Li-Lin
PIH-717X/7000/7600/7625 series
Rx100 software RX1_L1V8

Application Notes


Variable speed Pan/Tilt.
Zoom/Focus, Autofocus
16 full scene presets
2 preset patrols
4 alarm inputs driving to preset 1 - 4

Advanced Features

Tx400 Tx1000

Tx1500 DM Sprite/DS/DSL/DS2/BX2

Toggle Menu display

‘#’ 1

‘#’ WASH

1 ‘#’

*889 002 or *889 10 10 2

Enable Auto-Iris

‘#’ 2

'#' WIPE

2 ‘#’

*889 003 or *889 10 10 3

Dome reset step 1

‘#’ 3

'#' AUTOPAN

3 '#'

*889 004 or *889 10 10 4

Exit menu

‘#’ 4

'#' LIGHTS

4 '#'

*889 005 or *889 10 10 5


Procedure to program preset positions. The procedure must be followed to program new preset positions and also to re-
program existing positions.

The keystrokes shown below assume use of a Tx1000.
1) Select GOTO PRESET number to program eg 1
Hold PRESET tap 1
2) Move dome to new position using joystick and lens keys.
3) Select PROGRAM PRESET to save new position.
Press PROGRAM 1 1

To stop dome from running its own internal Autopan move joystick then press AUTOPAN.

RS485 connections between Rx100 and dome.

PIH717(DB15) or

PIH7000/7600

Description

Rx100

Pin

14

TXDI-

-Data

J3/C1

Pin

15

TXDI+

+Data

J3/C2


Notes:

The alarm output relay opens for approx 5 seconds upon power up. This can be used to signal power loss, etc.
A 2 minute datum mode is available. 2 minutes after the last manual command, the dome will either move to preset 1 or start an autopan. Fit link J6/1-2 to
enable this feature. J6/4-5 fitted = autopan, J6/3-4 fitted = goto preset 1.

All dome preset positions can be deleted using #3 followed by #4 within 1 second.
Check with the DM multiplexer manual for exact procedure for entering * commands.

IMPORTANT: Dome settings: Select dome address #1.

To aid diagnostics and confirm correct connection between the Rx100 and dome, the TEST link when shorted will drive the
dome LEFT until the short is removed. Whilst the Rx100 is sending data to the dome the GREEN DATA will flash.

V6 software – 1# now used to toggle menu display on/off. In previous versions this was used to toggle AUTOPAN which is
now not required with current generation of LiLin dome.