38

CODE

PHASES LIGHTS

DESCRIPTION

E7

The appliance is not able to measure the amount
of water loaded accurately (on models with turbine
flow-regulator only).

E8

Anomaly in the system which distributes water to
the basket (where installed).

E9

The maximum level of water for loading has been
exceeded (on models with turbine flow-regulator
only).

• The

E1, E2, E3, E4, E8, E9 alarms provoke the “forcing” to end

cycle of the running program.

• The

E5, E6 alarms interrupts the running program once the cause is

resolved, it will bring bach the execution of the program.

• The

alarm

E7 is visualized at the end of the cycle that comes,

however, brought to the end since the operation of the dishwasher is
not harmed.


To “reset” an alarm is necessary:

• Open and close the door, or turn off and on the machine. At this

point is possible to program the dishwasher again.



If the fault persists, call the authorised Technical Service Centre.




TECHNICAL DATA

Width

597

÷ 599 mm

Depth measured flush with the
outer edge of the control panel

Free standing: 600 mm
Semi-integrated: 570 mm

Height (depending on models)

Free standing: from 850 mm to 870 mm
from 890 mm to 910 mm
Semi-integrated: from 820 mm to 870 mm
from 860 mm to 910 mm

Capacity

14 Standard place settings

Water supply pressure

min. 0,05 - max. 0,9 MPa (min. 0.5 – max. 9 bar)

Electrical characteristics

See rating plate