Page 19 of 29






When no buttons in the Filter section are pressed, the filters come after the Equalizer section
With the INPUT button pressed, the filters come before the Equalizer section
When the DYN SC button is pressed, the filters are switched into the sidechain of the Dynamics
section. The term ‘sidechain’ and the process of sidechaining will be discussed in greater detail in
the overview of the Dynamics section.

Using Filters

DYN SC: The Filters are switched into the sidechain of the Dynamics section. The Equaliser can be
switched into the sidechain independently. Note that DYN SC overrides the INPUT function (see
below).

INPUT: Moves the Filters to put them in circuit immediately after the Channel Input section. This
allows the Filters to be used to clean up signals before compressing them. Selecting Dynamics ‘PRE
EQ’ will allow the compressed signal to be EQ’d.

INPUT

OUTPUT

Freq Hz

HPF

²t

18dB/Oct

acw

²t

acw

Freq kHz

LPF

12dB/Oct