4.3.9 Modem status command (MSC)

The Modem Status Command is used for software flow control.

Comman

d


1 octet

Length

1 octet

DLCI

1 octet

V.24 signals

1 octet

Break Signals

(optional)

1 octet


Command:

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 8

1 C/R

0 0 0 1 1 1

Figure 11: Modem status command (MSC)

C/R bit: Indicates whether the sequence is a command or a response.

Length:

Length = 2 , EA-Bit = 1



DLCI:

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 8

1 1

DLCI



V.24 signals:

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Bit 8

1

FC RTC RTR reserved

0 reserved

0 RING DCD

FC bit: Flow control, included in all multiplexer versions
FC = 1: no frames are accepted


The following bits for V24 status lines as described in this chapter are included in multiplexer
protocol version 3 only. However, if you wish to use the advantages of this version it is
absolutely necessary to switch on the version 3, otherwise version 1 will be used, see
Chapter 5.2.

Direction host application" module (for request only) MUX V3:
RTC: mapped to DTR

RTR: mapped to RTS
Bit 5, 6, 7, 8 are not valid.

Direction module
" host application (for request only) MUX V3:
RTC: mapped to DSR
RTR: mapped to CTS
RING: mapped to RING
DCD: mapped to DCD
Bit 5, 6 are not valid