4.4 Example: Establishing logical channels without parameter

negotiation

• Send AT+CMUX=0; wait for the response

• Send Request SABM for DLCI = 0; wait for the response
• Send Request SABM for all requested DLCIs; wait for the response

As a result the multiplexer is established and information / data can be transmitted
(

⇒ ready for Information Transfer).

Customer

µC

Closed Down

Closed Down

RequestStartUp

ResponseStartUp

ConfirmStartUp

IndicationStartUp

Disconnected

Disconnected

Serial

interface

Sta

rt

U

p

"A

T+CM

UX"

Connected

DLCI = 0

D

LC

Es

tab

lis

hm

en

t,

Cr

eat

e D

LCI =

0

Disconnected

DLCI = 0

Disconnected

DLCI = 0

RequestSABM

DLCI = 0

IndicationSABM

DLCI = 0

ResponseUA

DLCI = 0

ConfirmUA

DLCI = 0

Connected

DLCI = 0

Connected

DLCI = 1

D

LC

Es

tab

lis

hm

en

t,

Cr

ea

te

D

LCI

= 1

Disconnected

DLCI = 1

Disconnected

DLCI = 1

RequestSABM

DLCI = 1

IndicationSABM

DLCI = 1

ResponseUA

DLCI = 1

ConfirmUA

DLCI = 1

Connected

DLCI = 1

GSM engine µC

Figure 13: Establishing the multiplexer control channel and the logical channel