installation and external connection

installation and external connection

RS-422 Communication Port Connection (Multiple Units)

The RS-422/RS-232 converter is required to establish RS-422 communications.

- Follow the guidelines below to make connection between devices.

Connect TX(-) of one device to TX(-) of other one.

Connect TX(+) of one device to TX(+) of other one.

Connect RX(-) of one device to RX(-) of other one.

Connect RX(+) of one device to RX(+) of other one

Set a unique board ID for each product.

- Follow the guidelines below to make connection between the terminal device and the RS-422 9-pin

connector of the RS-422/RS-232 converter.

Connect RS-422 TX(-) to the RX(-) port of the converter.

Connect RS-422 TX(+) to the RX(+) port of the converter.

Connect RS-422 RX(-) to the TX(-) port of the converter.

Connect RS-422 RX(+) to the TX(+) port of the converter.

Connect the 9-pin connector of the RS-422/RS-232 converter to the COM port of the computer.

Install and launch the application (SAMS).

1.

2.

3.

4.

5.

1.

2.

3.

4.

5.

6.

T+ T- R+ R-

RxD

TxD

Power

RS-422/232
Converter

RS-232C

MAX. 1200m

HOST

TX-

TX+

RX-

RX+