8. SPECIFICATIONS


General and notes

All specifications mentioned hereafter apply to standard models only.
SONOSAX SAS SA reserves the right to modify these characteristics at any time without prior notice.

For measures and/or settings the reference is: 0dBu = 0.775V (i.e. + 6dBu = 1.55V).

Summary of characteristics

Frequency response :

10Hz to 200kHz ± 0.5dB

20Hz to 200kHz ± 0.1dB


Equivalent input noise :

-128dBu ( 20Hz to 200kHz - 150

source @ 60dB gain )


Input gain Fixed Steps :

60dB

48dB 36dB 24dB 12dB 0dB

Input gain Fine :

± 20dB from CAL Position ( 40dB end to end )

Fader gain :

selectable +12dB or +24dB

Global gain range:

fader @ 0dB

- 20dB to +80dB

fader @ +12dB

- 8dB to +92dB

fader @ +24dB

+4dB to +104dB


Overall dynamic range :

128dB

Input headroom :

24 dB


Crosstalk between 2 channels : better than 100dB 10Hz to 1kHz

better than 90dB 10Hz to 20kHz


Overall THD+N :


Main Level meters:

moving coil Peak Meters IEC-268-10 type 1 ( factory default )

internally selectable to IEC-268-10 type 2 or absolute Peak

large level scale from -32dB to +12dB

reading 0dB at nominal level

switchable to Level and Phase Correlation meter

battery

level

indication


LED's Level indicators :

red

+6dB

yellow

0dB nominal level

green -

10dB

green -

20dB

green -

40dB

overload indication: turns all leds ON 6dB before clipping

Led level reading accuracy: ± 0.1dB


Nominal output level :

+6dBu or +4dBu

0dB reading on all Peak level meters reflect the nominal level

An internal jumper sets the global nominal level of the entire mixer.

It automatically affects the setting of all peak-meters, output levels,

the internal 1kHz ref tone, the 0 setting of the limiters.