Brush Roll Belt

The brush roll belt on the upright vacuum cleaner drives the brush to agitate, sweep,
and comb the carpet nap. The belt should be checked regularly to be sure it is in good
condition. Replace the belt if it is stretching, cracking, or slipping. Cut away any hair or
thread wound around the brush roll or the belt pulley because the buildup could cause
the belt to rotate unevenly.

How to Replace A Worn Belt

NOTE: Turn off the switch and unplug the electrical cord before replacing belt.

Belt pulleys can become hot during normal use. To prevent burns, avoid
touching the belt pulley when servicing the drive belt.

IMPORTANT: Improper installation of the brush roll or brush roll belt could cause

carpet or cleaner damage.

1. Release cam locks to remove

bottom plate.

2. Pull up on belt to rotate it off the

motor pulley. Lift up on brush roll
and remove worn belt.

Check for brush wear (see Brush Roll
instructions).

3. Place new belt around brush roll.
4. Align brush roll pulley with belt

guide.

7. Place lower side of belt into belt

guide and pull to stretch the belt
around the left side of motor
pulley. Rotate pulley to secure belt
into groove.

8. Place slots of bottom plate over

tabs of cleaner base. Seat and
secure cam locks (refer to 1).

5. Place rubber end cap covers over

both end caps (flat side against
end cap). Align holes and secure.

6. Align end caps with slots in

cleaner base. Push brush roll into
base.

Ask for GENUINE EUREKA
replacement belts - No. 52100.

GENUINE

EUREKA PRODUCT

Look for the

symbol.

Belt
guide

Fan Cover

Motor Pulley

Brush Roll Pulley