Specification, Environment – Sierra Monitor Corporation ZSE30 User Manual

Page 9

Advertising
background image

ZSE30

ISE30

Rated Pressure Range

-100 to 100 kPa

0 to 1 MPa

Set Pressure Range

-101 to 101 kPa

-0.1 to 1 MPa

Withstand Pressure

500 kPa

1.5 MPa

Setting and Display Resolution

0.2 kPa

0.001 MPa

Fluids

Air, inert gases and incombustible gases

Power Supply Voltage

12 to 24V DC,

±10%,ripple (p-p) 10% or less(Protected against inverse connection)

Current Consumption

45mA or less (No load)

Switch Output

Note 1)

NPN or PNP open collector output .1 output

Max. Load Current

80mA

Max. Impressed Voltage

30V (During NPN output)

Residual voltage

1V or less (@80mA load current)

Response Time

2.5ms or less (chattering-proof function working :20,160,640 or 1280ms selectable)

Short Circuit Protection

Provided

Repeatability

±0.2%F.S. ±2 digits or less

±0.2%F.S.±1 digit or less

Voltage Output
Note 2)

Output Voltage : 1 to 5V

±2.5%F.S. or less (within rated pressure range)

Linearity :

±1%F.S. or less, Output impedance : Approx. 1kΩ

Analog
Output Current Output

Note 3)

Output Current : 4 to 20mA

±2.5%F.S. or less (within rated pressure range)

Linearity :

±1%F.S. or less

Max. Load Impedance : 300

Ω (@12VDC), 600Ω (@24VDC) Min. Load Impedance : 50Ω

Hysteresis Mode

Hyster
esis

Window Comparator

Mode

Variable(from 0)

Display Method

3.5 digits 7-segment display, dual-color display(red/green) Sampling rate:5 times/1 sec

Indicator Accuracy

±2%F.S. ±2 digits (@25±3°C)

±2%F.S. ±1 digit (@25±3°C)

Indicator Lamp

Lit when ON (Green)

Temperature Characteristic

±2%F.S. or less (@25°C reference)

Enclosure IP40
Ambient Temperature

Operation : 0 to 50

°C, Storage : -10 to 60°C (No condensation or no freezing)

Ambient Humidity

Operation

⋅Storage : 35 to 85%RH (No condensation)

Withstand Voltage

1000VAC,1 minute (between lead block and case)

Insulation Resistance

50M

Ω or more @500VDC M (between lead block and case)

Vibration proof

10 to 150 Hz, 1.5mm double amplitude, 2 hours each in directions of X, Y and Z respectively

Impact proof

100m/s

2

, 3 times each in directions of X, Y and Z respectively

Standard

CE marking, UL/CSA(E216656)

Note 1) Analog output cannot be selected when switch output is selected.
Note 2) Both switch output and current output cannot be selected simultaneously when voltage output is
selected.
Note 3) Both switch output and voltage output cannot be selected simultaneously when current output is
selected.

Piping specification

Model

01

T1

C4H

C6H

N7H

C4L

C6L

N7L

Port size

R1/8

M5

×0.8

NPT1/8

M5

×0.8

One-touch fitting
straight type

φ4mm

φ5/32inch φ6mm φ1/4inch

One-touch fitting
elbow type

φ4mm

φ5/32inch φ6mm φ1/4inch

Sensor pressure sensing part: silicone, Pipe port: C3602 (electroless nickel plating),

Material

O-ring: HNBR

O-ring: NBR

O-ring: NBR, Fitting: PBT

Lead wires with
connector included

(2m)

81g 76g

78g

Mass

(Weight)

Lead wires with
connector not included

43g 38g

40g

Environment

-8-

PS##-OMF0010-C

Specification

Advertising
This manual is related to the following products: