Trouble Shooter

Problem: Controller display is

blank. No heat in kiln.

Is the kiln connected to the power?

Has the circuit breaker tripped or fuse blown?

Is power reaching the wall receptacle?

Test with a voltmeter or a test light if you are not sure.

Has the kiln switch box

½ amp fuse blown?

The kiln’s ½ amp fuse is

located in the kiln switch

box. Remove by pressing

the fuse holder and turning

counter-clockwise half a

turn. Check the fuse by

placing the probes of an

ohmmeter on the ends

of the fuse. If the ohm-

meter reads less than

an ohm (digital meter)

or reads 0 ohms (ana-

log meter), the fuse is

okay. If the reading is

OPEN (digital meter)

or infinity/no needle

movement (analog me-

ter), the fuse is bad.

Replacement fuse:

AGC 1/2 A 250V AC

Is the controller receiving power? Test the power IN-

PUT connections on the back of the controller with a

voltmeter.

Controller Power Input Test

Unplug the kiln. Remove the 4 screws holding the con-

troller faceplate to the switch box. Lift faceplate out of box

and let the board hang on the box with the back of the board

facing you. Plug the kiln back in. Touch voltmeter probes

Touch the voltmeter probes to the white and orange wires to test voltage

going to the controller. The voltmeter must be in AC mode.

Selecting °F or

°C Display

The controller can display temperature in either °F or

°C. If your controller shows a small display dot in the lower

right corner of the display, the temperature shown is °C. No

dot means °F. To change temperature display:

UNPLUG kiln or disconnect power.
Remove the four screws that hold the controller to

the front of the kiln. Carefully remove the controller

from the kiln. Leave the wires attached to the con-

troller.

Look at the back of the controller. You will find a set

of connector pins near the bottom labeled “C/F.”

When a jumper is placed on the C/F pins, the display

reads °F. When the jumper is removed, displayreads

°C. Remove or insert the jumper as desired. (You

can purchase the jumper from a computer supply

store if necessary.)

Install the controller being careful not to jar compo-

nents on the back of the controller against the kiln

case.

The C/F jumper terminal is on the back of the controller, circled above.