Chart 1, Previous | home | next – SATO M 8400RVe User Manual

Page 3

Advertising
background image

<

previous | home | next

>

EZ Manual: M-8400RVe

3

Barcode SATO International Pte Ltd

Electric Checks and Adjustments

Chart 1

Dial test point

Comment

Voltage

Voltage Range

Check pin on TP Test Module and Main PCB

Adjustment to VR

0

DC power Supply

+5.0 VDC

+4.8V to +5.2V

CH3A(+5.0V) - CH1A(GND)

N/A

1

DC power Supply

+2.0 VDC

+1.9V to +2.1V

CH4A(+2.0V) - CH1A(GND)

N/A

2

DC power Supply

+3.3 VDC

+3.1V to +3.5V

CH5A(+3.3V) - CH1A(GND)

N/A

3

DC power Supply

+24.0 VDC

+23.5V to +24.5V

CH6A(+24.0V) - CH1A(GND)

N/A

4

I-Mark Sensor Level

CH1B(+8.4V) - CH1A(GND)

VR5

5

Gap sensor Level

CH2B - CH1A(GND)

VR4

Low level (Set the blank area

on the sensor) = A

High level (Set the I-mark

on the sensor) = B

High level - Low level =

A - B = more than +0.9V

Low level (Set the label backing liner or the

centre hole [in case of the centre hole tag]

on the sensor) = C

High level (Set the label or

tag on the sensor) = D

High level - Low level =

C - D = more than +1.0V