Installation 5, Unplug the pump, Performance – Simer Pumps MINI-VAC M40P-04 User Manual

Page 5: Troubleshooting chart

Advertising
background image

Installation

5

For parts or assistance, call Simer Customer Service at

1-800-468-7867

UNPLUG THE PUMP

Unplug the pump before all the water is
completely gone.
DO NOT RUN PUMP DRY!

PERFORMANCE

The pump will deliver 350 gallons/1325
liters per hour with an unrestricted dis-
charge line. If the discharge line is restrict-
ed or raised and the pressure on the pump
outlet port increases, it will pump less
water.
NOTICE: This pump’s motor has brushes.
Inspect the brushes frequently; replace
them if they’re worn.

Unplug

5

SYMPTOM

PROBABLE CAUSE(S)

CORRECTIVE ACTION

Pump stops without

Pump has overheated

Wait for overload to reset; pump will automatically

warning

and thermal overload

restart

has tripped

Discharge hose too long

Use shorter hose or reduce lift

or discharge lift higher
than 28’

Pump Won’t Prime

Pump body not oiled

Add oil through inlet port (see Page 3)

Suction hose too long or

Use 1/2

"

Suction hose, 25’ long or less

too small

(the shorter the hose, the better)

Worn impeller

Replace impeller

Suction leaks

Replace hose washer, check for leaks in hose

Suction hose kinked

Straighten out suction hose

or coiled

Pump leaks

Shaft U-cup seal leaks

Replace shaft seal

Cover O-Ring leaks

Replace cover O-Ring

Pump runs, pumps

Worn impeller

Replace impeller

little or no water

Bad motor brushes

Replace motor brushes

Bad U-cup shaft seal

Replace shaft seal

(pump will leak)

Suction or discharge hose

Straighten out hose

kinked or coiled